SECTION 02844 / 02845 / 02870
PRECAST GFRC SITE AMENITIES WITH StoneForm™ OPTION

PART 1 - GENERAL

1.01 SUMMARY

A. Section Includes:

1. Factory Finished Units: Provide Stonewear finished glass fiber reinforced concrete (GFRC) precast planters with StoneForm™ enclosure around preengineered reinforcing steel cage for complete installation.

1.02 REFERENCES

A. American Society for Testing and Materials (ASTM):

1. ASTM C 33-86: Concrete Aggregates.

2. ASTM C 150-86: Portland Cement.

3. ASTM C 979-82(1986): Pigments for Integrally Colored Concrete.

B. American Welding Society (AWS) D1.1-88: Structural Welding Code, Steel.

C. Prestressed Concrete Institute (PCI) MNL-128-87: Recommended Practice for Glass Fiber Reinforced Concrete Panels.

D. Prestressed Concrete Institute (PCI) MNL-117-77: Manual for Quality Control for Plants and Production of Architectural Precast Concrete Products.

1.03 SUBMITTALS

A. Submit the following in accordance with requirements in Division 1.

B. Product Data: Submit Stonewear literature.

1. Manufacturer Certification: Indicate installer is acceptable.

C. Shop Drawings: Show detailing including component dimensions, drainage, and accessories if applicable.

D. Samples: Minimum 4" x 4" GFRC samples indicating finish and color.

1.04 QUALITY ASSURANCE

A. Fire Rating: Provide units conforming with Underwriters Laboratories (UL), Class A. maximum 25 flame spread; maximum 25 smoke contributed, ASTME 84-89.

B. Installer Qualifications: Firm with minimum five years successful experience installation of precast concrete planters, concrete placement, and acceptable to planter manufacturer.

1.05 DELIVERY, STORAGE AND HANDLING

A. Handling: Handle site amenities in positions consistent with their shape and design; lift and support only from points under planter unless specific lift embeds are specified in shop drawings.

B. Protection: Protect site amenities to prevent staining, chipping, and spalling; damaged units will be rejected.

1.06 SITE CONDITIONS

A. Services: Do not install units until mechanical and electrical services located behind units are completed, tested, and approved.

B. Subsurface excavation and foundations per plans and specifications if applicable.

PART 2 - PRODUCTS

2.01 MANUFACTURERS

A. Stonewear, Inc., 2900 Lockheed Way, Carson City, NV 89706 775-883-8300

2.02 MATERIALS

A. GFRC site amenities:

1. Site Amenities: Glass fiber reinforced concrete (GFRC) precast site amenities suitable for interior/exterior and high traffic applications.

a. Cement: ASTM C 150, use only one brand and type of cement throughout Project.

b. Glass Fibers: Alkali resistant (AR) glass fibers produced specifically for use in glass fiber reinforced concrete; manufacturer's standard types.

1) Glass Content of GFRC unit to be minimum 3% in minimum 1" - 1 1/2" length.

c. Aggregates: Clear silica sand passing No. 16 (1.18mm) sieve; washed, dried, and free from deleterious materials; provide type with successful history of use in GFRC or as specified by manufacturer.

d. Compressive Strength: Minimum 3000 psi.

e. Shell Thickness: 3/8" to 5/8", or as specified per plans and specifications.

f. Density: Approximately 120 pcf.

g. Polymer Admixture: Stonewear’s standard acrylic thermoplastic copolymer.

h. All planters are water tight. No membranes are required or used with GFRC planters.

2. Finishes:

a. Factory Finished Units: Stonewear’s standard finish as selected by Architect and indicated on Drawings.

1) Cement: White or grey as consistent with final finish.

2) Facing Aggregates: ASTM C 33 (less gradation), clean, hard, durable, inert, and free of staining and deleterious materials; as required to match approved samples.

3) Color: ASTM C 979, pure, non-fading mineral oxides which do not impair strength of GFRC designed and mixed to provide color matching approved samples; maximum 10% cement weight.

4) Applied finishes: ASTMD 4060 waterborne crosslinked acrylic 49.5 +/- 2% solids by weight providing 1000 cycles per .001 inch resistance to abrasion.

B. Accessories: Stonewear’s standard materials and accessories as required for planters as indicated on drawings.

C. Brackets and Anchors: Unexposed plates, angles and supports may be galvanized steel; separate dissimilar materials to prevent electrolytic action.

D. Fasteners: Type required for specific usage; provide concealed fasteners except where specifically approved.

2.03 FABRICATION

A. Standard: Comply with PCI MNL-128 recommended practice for glass fiber reinforced concrete panels, including Appendix G, Polymer Modified Glass Fiber Reinforced Concrete Panels.

B. Units: Manufacture and cure units to ensure similarity of dimension and finish throughout, free from casting joint marks, grain, and obvious defects.

C. Inserts and Embedments: Embed into units in manner to develop full strength required for insert and embedment without weakening unit; maintain sufficient embedment for design requirements.

D. Fabrication Tolerances: Prefabricate site amenities within following maximum differences from dimensions indicated in Contract Documents;

1. Dimension: Plus of minus 1/8" in any direction, noncumulative.

2. Material Thickness: Plus 1/4" and minus 0".

3. Total Unit Thickness: Plus 1/4" and minus 1/8".

4. Insert Locations: Plus or minus 1/4".

2.04 SOURCE QUALITY CONTROL

A. Factory Quality Control Program: Stonewear shall maintain quality control program throughout fabrication of site amenities.

B. Standard: Conform with requirements of PCI MNL-117 for quality control.

C. Testing: Quality control program shall include twenty-four hour water test of all units with records maintained at place of manufacture.

PART 3 - EXECUTION

3.01 EXAMINATION

A. Inspection: Check Project dimensions affecting installation; beginning of work signifies acceptance of conditions.

3.02 INSTALLATION

A. Placement: Install units in accordance with manufacturer's instructions, including methods for moving and placement provided by manufacturer.

3.03 CLEANING

A. Clean soiled units using methods recommended by unit manufacturer; use extreme care to prevent damage to unit surfaces and surrounding materials.

3.04 PROTECTION

A. Protection: Repair or replace items damaged or marred during construction.

B. Patching:

1. Factory Finished Units: Mix and place patching mixtures to match color and texture of surrounding finish; replace units which cannot be acceptably patched.

a. Patch Acceptance: Patches noticeable from a distance of 5'-0" are not acceptable.

E N D  O F  S E C T I O N

 

 